Final exam
Energy Systems and the Electric Grid
Before you start
- 20 questions, drawn at random from a pool of 32.
- Pass mark: 70%. Your final score is 30% practice + 70% exam.
- No time limit, but finish within 3 hours. You can move between questions before you submit.
- Failed? Review the lessons and try again: every attempt gets a new set of questions.
Question 1 of 20Work it out
A space heater draws 1,500 W and runs 6 hours a day for 30 days. Electricity costs $0.20/kWh. What does it cost to run for the month, in dollars?
Question 2 of 20Choose one
A news story says a new battery "stores 100 megawatts." What is wrong with this statement?
Question 3 of 20Fill in the blanks
Fill in the blanks
One kilowatt-hour equals BTU, so a plant with a heat rate of 6,824 BTU/kWh is percent efficient.
Question 4 of 20Work it out
Steam enters a turbine at 600 °C and the condenser is at 40 °C. What is the Carnot efficiency limit, to the nearest whole percent?
Question 5 of 20Choose one
Which power source generates electricity without spinning a turbine?
Question 6 of 20True or false
Combined heat and power plants reach high overall efficiency by using the heat that ordinary power plants reject to the environment.
Question 7 of 20Work it out
A line carries 50 MW at 250 kV with a resistance of 10 ohms. What is the power lost as heat in kW?
Question 8 of 20Choose one
Why did alternating current win over direct current for early power grids?
Question 9 of 20Put in order
Order these grid components as electricity passes through them from a wind farm to a home.
Drag the items, or use the arrow buttons, to put them in order.
- High-voltage transmission line
- Wind turbine generator
- Step-down substation
- Step-up transformer at the wind farm
- Distribution line and neighborhood transformer
Question 10 of 20Choose one
Grid frequency in a 50 Hz system rises to 50.2 Hz. What does this indicate?
Question 11 of 20Select all that apply
Which of the following provide fast frequency support when a large generator trips? Select all that apply.
Select all that apply.
Question 12 of 20True or false
Solar panels and batteries connected through standard inverters naturally provide the same inertia as large spinning generators.
Question 13 of 20Work it out
A region's peak demand is 25 GW and planners require an 18% reserve margin. How many GW of capacity are needed?
Question 14 of 20Work it out
A 200 MW solar farm has a 24% capacity factor. How many MWh does it produce in a year?
Question 15 of 20Choose one
Which explains a gas peaker's capacity factor of about 5%?
Question 16 of 20Work it out
Ignoring discounting, a plant costs $300 million to build, $5 million a year to operate, and produces 500,000 MWh a year for 30 years. What is its levelized cost in $/MWh?
Question 17 of 20Choose one
On a grid with a lot of solar, why does net load rise steeply in the early evening?
Question 18 of 20True or false
Linking wind farms spread across a large region produces steadier combined output than a single wind farm.
Question 19 of 20Choose one
Why can wholesale electricity prices become negative?
Question 20 of 20Work it out
A battery is rated 60 MW / 240 MWh. If it discharges at 40 MW, how many hours can it run?
Question 21 of 20Work it out
A storage system takes in 500 MWh and delivers 435 MWh. What is its round-trip efficiency in percent?
Question 22 of 20Match the pairs
Match each storage technology to its typical role.
Tap an answer, then tap the place where it belongs (or drag it there).
- Lithium-ion battery
- Pumped hydro
- Green hydrogen
- Iron-air battery
Question 23 of 20What would you do?
What would you do?
A city utility sees its evening peak rising and must choose how to meet it for the next decade. Which approach is likely cheapest and lowest-emission to try first?
Question 24 of 20Choose one
A household's EV charges from 6 p.m. to 9 p.m. every day. Which change helps the grid most without reducing the miles the car can drive?
Question 25 of 20True or false
Interconnection queues in the US contain more proposed generation and storage capacity than is currently installed on the grid.
Question 26 of 20Work it out
Offers: 15 GW hydro at $5/MWh, 20 GW gas at $50, 10 GW older gas at $80, 5 GW peakers at $200. Demand is 38 GW. What is the uniform clearing price in $/MWh?
Question 27 of 20Choose one
Why are local distribution wires usually run as a regulated monopoly even in competitive electricity markets?
Question 28 of 20Select all that apply
Which factors contributed to the February 2021 Texas power crisis? Select all that apply.
Select all that apply.
Question 29 of 20Work it out
A grid is 30% coal at 950 g CO2/kWh, 30% gas at 400 g CO2/kWh and 40% zero-carbon. What is its average carbon intensity in g CO2/kWh?
Question 30 of 20Choose one
Why do many studies find that some firm low-carbon power lowers the cost of a 100% clean grid?
Question 31 of 20Work it out
A heat pump has a COP of 3.5 and uses 2,000 kWh of electricity over a winter. How much heat does it deliver, in kWh?
Question 32 of 20Spot the mistake