Find a course

Module 6: AC CircuitsLesson 12 of 1217 min

Reactance, Impedance and AC Power

Calculate capacitive and inductive reactance, combine them with resistance into impedance, and use phasors, filters, resonance and power factor.

Step 1 of 12Learn

Why the speaker cable filter works

A two-way loudspeaker sends bass notes to a big woofer and treble to a tiny tweeter. The splitter inside, called a crossover, is often just a capacitor and an inductor. The capacitor passes high frequencies to the tweeter and blocks low ones; the inductor does the opposite for the woofer. The secret is that capacitors and inductors oppose AC by an amount that depends on frequency.

This opposition is called reactance (X), measured in ohms:

Capacitive reactance: X_C = 1 / (2πfC) Inductive reactance: X_L = 2πfL

  • A capacitor's reactance falls as frequency rises. At DC (f = 0) it's infinite: an open circuit. At high frequency it approaches a short.
  • An inductor's reactance rises with frequency. At DC it's zero: a short. At high frequency it blocks.

Example: a 10 µF capacitor at 60 Hz: X_C = 1 / (2π × 60 × 10-5) ≈ 265 Ω. At 6 kHz, it drops to 2.65 Ω.

A 10 mH inductor at 60 Hz: X_L = 2π × 60 × 0.01 ≈ 3.77 Ω. At 6 kHz, 377 Ω.

Unlike resistance, reactance doesn't dissipate energy. The component stores energy for part of each cycle and returns it during the next.

Step 2 of 12Try the calculator

Reactance calculator

Compare capacitive and inductive reactance at any frequency.

Capacitive reactance X_C
265.26 Ω
Inductive reactance X_L
3.77 Ω
Resonant frequency of this L and C
503.3 Hz

Step 3 of 12Practice · Work it out

What is the reactance of a 1 µF capacitor at 1 kHz? Round to the nearest ohm.

Step 4 of 12Practice · Chart

Reactance of a 1 µF capacitor and a 10 mH inductor

Capacitive reactance falls with frequency; inductive reactance rises. Where they cross, an LC circuit resonates.

Tap the first frequency in the chart where the inductor opposes current more than the capacitor.

Tap the point that answers the question, then press Check.

Reactance of a 1 µF capacitor and a 10 mH inductorLine chart with 6 categories: 100 Hz: X_C (1 µF) 1,592 Ω, X_L (10 mH) 6 Ω; 500 Hz: X_C (1 µF) 318 Ω, X_L (10 mH) 31 Ω; 1 kHz: X_C (1 µF) 159 Ω, X_L (10 mH) 63 Ω; 2 kHz: X_C (1 µF) 80 Ω, X_L (10 mH) 126 Ω; 5 kHz: X_C (1 µF) 32 Ω, X_L (10 mH) 314 Ω; 10 kHz: X_C (1 µF) 16 Ω, X_L (10 mH) 628 Ω.0 Ω500 Ω1,000 Ω1,500 Ω2,000 Ω100 Hz500 Hz1 kHz2 kHz5 kHz10 kHzFrequency
Reactance of a 1 µF capacitor and a 10 mH inductor
FrequencyX_C (1 µF)X_L (10 mH)
100 Hz1,592 Ω6 Ω
500 Hz318 Ω31 Ω
1 kHz159 Ω63 Ω
2 kHz80 Ω126 Ω
5 kHz32 Ω314 Ω
10 kHz16 Ω628 Ω

Step 5 of 12Learn

Impedance and phasors

Real components combine resistance and reactance. Their total opposition to AC is the impedance Z, also in ohms. But you can't just add R and X, because their voltages are 90° out of phase: a resistor's voltage is in phase with the current, while a reactance's voltage is 90° ahead (inductor) or behind (capacitor).

Engineers draw these as phasors, arrows whose length is the amplitude and whose angle is the phase. Resistance points along the horizontal axis; inductive reactance points up, capacitive reactance points down. In a series circuit, the impedance is the arrow sum:

|Z| = √(R² + X²), where X = X_L − X_C

phase angle θ = arctan(X / R)

Example: a series circuit with R = 30 Ω and X_L = 40 Ω. |Z| = √(900 + 1600) = 50 Ω, and θ = arctan(40/30) ≈ 53.1° (current lags voltage). On 120 V RMS, the current is 120 / 50 = 2.4 A.

Notice that the resistor alone drops 2.4 × 30 = 72 V and the inductor 2.4 × 40 = 96 V. These add to 168 V, more than the 120 V supply. That isn't a KVL violation: the voltages peak at different times, and their phasor sum is √(72² + 96²) = 120 V.

Mathematically, engineers write impedance as a complex number, Z = R + jX, where j = √−1. Ohm's law V = IZ then works for AC exactly as it does for DC.

Step 6 of 12Practice · Work it out

A series circuit has R = 60 Ω, X_L = 120 Ω and X_C = 40 Ω. What is the magnitude of its impedance, in ohms?

Step 7 of 12Learn

Filters and resonance

Frequency-dependent reactance makes filters possible. The simplest is the RC low-pass filter: a resistor in series, then a capacitor to ground, with the output across the capacitor. At low frequencies, X_C is large and most of the signal appears at the output. At high frequencies, X_C is small and the capacitor shorts the signal to ground.

The boundary is the cutoff frequency:

f_c = 1 / (2πRC)

At f_c, the output has dropped to 70.7% of the input (−3 dB), and the phase shift is 45°. Above it, the output falls by half for every doubling of frequency. Swap R and C and you get a high-pass filter.

Example: R = 1.6 kΩ and C = 100 nF give f_c = 1 / (2π × 1600 × 10-7) ≈ 995 Hz, about 1 kHz.

When a circuit has both L and C, something special happens at the frequency where X_L = X_C. The reactances cancel, leaving only resistance. This is resonance:

f0 = 1 / (2π√(LC))

In a series RLC circuit at resonance, impedance is at its minimum and current at its maximum. Radios use resonance to select one station: turning the tuning knob changes C, moving f0 to the station's frequency. Resonance also explains why poorly designed circuits can ring or oscillate.

Step 8 of 12Explore

RC low-pass filter response

Output amplitude as a fraction of the input, versus frequency (x in Hz). The readout shows the cutoff frequency.

00.250.50.751 01,0002,0003,0004,0005,000
Cutoff frequency
995 Hz
Gain at 2 × cutoff
0.447

Step 9 of 12Flashcards

Key AC formulas

Tap a card to flip it.

Step 10 of 12Learn

Real power, reactive power and power factor

When voltage and current are out of phase, multiplying V_rms by I_rms overstates the useful power. The true picture uses three quantities:

  • Real power P, in watts: energy actually converted to heat, light or motion. P = V_rms × I_rms × cos θ
  • Reactive power Q, in volt-amperes reactive (var): energy that sloshes back and forth between source and reactances each cycle, doing no net work.
  • Apparent power S, in volt-amperes (VA): S = V_rms × I_rms. They form a right triangle: S² = P² + Q².

The ratio P / S = cos θ is the power factor (PF). A pure resistor has PF = 1. The earlier R = 30 Ω, X_L = 40 Ω circuit has cos 53.1° = 0.6: on 120 V at 2.4 A, S = 288 VA, but only P = 288 × 0.6 = 172.8 W is useful. You can check: I²R = 2.4² × 30 = 172.8 W, because only the resistor dissipates energy.

Why it matters: utilities must supply the full current, including the reactive part, through their wires and transformers. Large industrial motors are inductive and drag power factor down, so factories add capacitor banks whose leading current cancels the motors' lagging current, raising PF toward 1. Many utilities charge industrial customers for poor power factor.

Step 11 of 12Practice · What would you do?

What would you do?

A factory's motors draw 100 A at a power factor of 0.7. An engineer proposes installing capacitor banks. What will happen to the current drawn from the utility if the power factor rises to about 0.95, with the same real power?

Step 12 of 12Practice · Work it out

A series circuit draws 5 A RMS from a 230 V RMS supply with a phase angle of 60°. What is the real power in watts?