Most failures start in the first five minutes

Ask experienced makers what causes most failed prints and the answer is almost always the same: the first layer. If it doesn't stick evenly, the part can shift, curl or break free halfway through, turning into a nest of plastic "spaghetti."

A good first layer depends on the distance between the nozzle and the bed across the whole surface. That distance must be roughly equal to the first-layer height set in the slicer, often 0.2–0.3 mm, everywhere on the bed.

Bed leveling (more precisely, tramming) makes the bed parallel to the nozzle's path:

  • Manual leveling: heat the bed and nozzle to printing temperature, home the printer, then slide a sheet of ordinary printer paper between nozzle and bed at each corner. Turn the leveling knobs until you feel slight drag on the paper. Repeat around the bed twice, since adjusting one corner affects the others.
  • Automatic bed leveling (ABL): a probe measures the bed at a grid of points and the firmware builds a mesh, raising and lowering the nozzle slightly as it moves to follow small dips and bumps. ABL compensates for a slightly warped bed but doesn't replace a reasonably trammed one.

Heat matters because metal expands: a bed leveled cold can be off by a noticeable fraction of a millimeter once it reaches 60–100 °C.

First layer height: nozzle too high leaves round separate lines, correct height gives slightly flattened touching lines, too low scrapes thin transparent linesToo highJust rightToo lowround, not stuckslightly flat, touchingthin, scraped

Step 2 of 12Practice · Put in order

Put the steps of manual bed leveling in a sensible order.

Drag the items, or use the arrow buttons, to put them in order.

  1. Move the nozzle over the first corner
  2. Repeat for every corner, then check all corners again
  3. Adjust the knob until a sheet of paper drags slightly
  4. Home all axes
  5. Heat the bed and nozzle to printing temperature

Step 3 of 12Learn

Z offset: dialing in the squish

Even with a level bed, the overall nozzle height must be right. The Z offset is a fine adjustment, often in 0.01–0.05 mm steps, that moves the whole first layer up or down. Most printers let you adjust it live while the first layer prints, a process called baby-stepping.

Watch the first layer and compare it with three cases:

  • Too high: lines are round, like separate strands of spaghetti, with gaps between them. They don't stick well and may drag around with the nozzle.
  • Just right: lines are slightly flattened and fuse with their neighbors into a smooth sheet. Running a fingernail across the surface feels even.
  • Too low: lines are very thin or transparent, the surface looks rough with ridges, the extruder may click as plastic can't escape, and the nozzle can scrape the bed.

A dedicated first-layer test print, such as a single-layer square in each corner and the center, makes judging easier. Once it looks right, save the Z offset; you'll only need to revisit it after changing nozzles, build sheets or the probe.

Cleanliness is the other half. Fingerprints leave oils that ruin adhesion. Wash PEI sheets with warm water and dish soap now and then, wipe with isopropyl alcohol between prints, and handle the sheet by its edges.

Step 4 of 12Practice · Sort into groups

Classify each first-layer observation.

Tap an item, then tap its group (or drag it there).

Step 5 of 12Compare

Reading the first layer

AspectToo highJust rightToo low
Line shapeRound, like spaghettiSlightly flat, fusedThin, see-through, ridged
GapsVisible between linesNoneNone, but rough ridges
AdhesionLines lift or dragHolds well, peels when coolHolds, but bottom bulges
FixLower the Z offsetSave the settingRaise the Z offset

Step 6 of 12Learn

Calibration prints that pay for themselves

Beyond the first layer, a handful of calibration tests tune a printer to a specific filament. Run them when you get a new printer or switch to a new brand or type of filament:

  1. Temperature tower. A tall test that changes the nozzle temperature every few millimeters. Pick the temperature with the best balance of surface finish, bridging, overhangs and minimal stringing.
  2. Flow rate (also called extrusion multiplier). Prints a set of small patches or a thin-walled cube. Too much flow makes walls bulge and top surfaces rough; too little leaves gaps. Most filaments land between 90% and 105%.
  3. Retraction test. Prints several thin towers far apart. Increase retraction distance or speed until the strings between them disappear.
  4. Pressure advance or linear advance. Compensates for the lag between extruder movement and plastic actually leaving the nozzle, sharpening corners at speed.
  5. Dimensional check. Print a 20 mm cube and measure with calipers. Errors of ±0.1 mm are normal; larger, consistent errors point to belt tension or steps-per-millimeter settings.

Many modern printers and slicers include these tests built in, and some printers calibrate flow and vibration automatically. Record the results in a named filament profile so you never repeat the work.

Step 7 of 12Diagram

The calibration loop

The calibration loopCycle diagram: Print a test → Inspect and measure → Adjust one setting → Save the profile.One changeat a timePrint a testInspect andmeasureAdjust onesettingSave the profile

Tap a shape with to see more.

Print a test

Temperature tower, flow patches, retraction test or a calibration cube.

Inspect and measure

Use calipers and compare against the designed size and good examples.

Adjust one setting

Change only one value so you know what made the difference.

Save the profile

Name it after the filament brand and color so you can reuse it.

Step 8 of 12Practice · Work it out

You print a calibration cube designed to be 20.00 mm wide and measure it at 20.30 mm in X. By what percentage is it oversized? Give one decimal place.

Step 9 of 12Try the calculator

Dimensional accuracy checker

Measure a test print with calipers. Errors around 0.1 mm are normal; consistent larger errors point to flow or calibration problems.

Error
0.1 mm
Error in percent
0.5 %

Step 10 of 12Note

Step 11 of 12Practice · What would you do?

What would you do?

After moving his printer to a new desk, Omar's prints keep detaching from one corner of the bed. The other three corners look fine. What is the most likely fix?

Step 12 of 12Practice · True or false

Automatic bed leveling makes manual tramming of a badly tilted bed completely unnecessary.