Find a course

Module 1: Electricity FundamentalsLesson 2 of 1311 min

AC Power and How It Reaches Your Home

Follow electricity from power plant to outlet, see why the grid uses AC at high voltage, and how a US home gets both 120 V and 240 V.

Step 1 of 13Learn

From power plant to wall outlet

The electricity in your outlet was generated moments ago, often hundreds of kilometers away, and traveled through a chain of equipment to reach you.

  1. Generation. Power plants spin generators (using steam from gas, coal or nuclear fuel, falling water or wind) or convert sunlight directly with solar panels. Generators typically produce several thousand to around 25,000 volts.
  2. Step-up transformers at the plant raise the voltage to hundreds of thousands of volts for long-distance transmission.
  3. Transmission lines, the tall steel towers you see crossing the countryside, carry this high-voltage power across regions.
  4. Substations near towns use transformers to step the voltage down to distribution levels, often in the range of about 4,000 to 35,000 volts.
  5. Distribution lines on poles or underground carry power along streets.
  6. A service transformer, the gray can on a pole or green box on a pad near your home, steps it down to the voltage your home uses.
  7. Service wires bring power to your meter and then to your service panel.

Why such high voltages for transmission? Because power lost as heat in wires equals I2 × R. For a given amount of power, raising the voltage lowers the current. Ten times the voltage means one-tenth the current and one-hundredth the heat loss. Transformers make these voltage changes simple and efficient, but they only work with alternating current, which is one big reason the grid uses AC.

Step 2 of 13Practice · Put in order

Put the stages of getting electricity to a home in order.

Drag the items, or use the arrow buttons, to put them in order.

  1. A substation steps the voltage down for local distribution
  2. The meter and service panel deliver it to home circuits
  3. A step-up transformer raises it to very high voltage
  4. A service transformer near the home lowers it to household voltage
  5. A generator at a power plant produces electricity
  6. Transmission lines carry it across long distances

Step 3 of 13Practice · Diagram

From power plant to outlet

At which stage is the voltage at its highest?

Tap the shape that answers the question, then press Check.

From power plant to outletProcess diagram: Generator → Step-up transformer → Transmission lines → Substation → Distribution lines → Service transformer → Meter and panel.GeneratorStep-uptransformerTransmissionlinesSubstationDistributionlinesServicetransformerMeter andpanel
Generator

A spinning generator produces AC, usually at 10,000–25,000 V.

Step-up transformer

Raises voltage to hundreds of thousands of volts so less current (and less heat loss) is needed.

Transmission lines

Tall towers carry power long distances at very high voltage.

Substation

Steps voltage down for local distribution lines.

Distribution lines

The lines along streets, often a few thousand volts.

Service transformer

The can on a pole or green box on a pad that drops voltage to 120/240 V.

Meter and panel

The meter measures your use; the panel splits power into circuits.

Step 4 of 13Learn

Alternating current

The electricity from a battery is direct current (DC): it flows steadily in one direction. Household electricity is alternating current (AC): its direction reverses many times a second. In North America it completes 60 cycles per second (60 Hz); in most of Europe, Asia, Africa and Australia, 50 Hz.

If you graphed the voltage at a US outlet, you'd see a smooth wave rising to a peak of about +170 volts, falling through zero to about −170 volts and back, 60 times a second. The "120 volts" we quote is an effective average called the RMS value: AC at 120 V RMS delivers the same heating power as 120 V DC.

AC won out for the grid in the late 1800s, after a famous rivalry between Thomas Edison's DC systems and the AC systems backed by George Westinghouse and Nikola Tesla. The deciding advantage was the transformer, which can raise or lower AC voltage efficiently with no moving parts. That made long-distance transmission practical.

Today, DC is making a comeback in specific places. Very long high-voltage DC lines carry power between regions efficiently, and inside your home, every phone, laptop, LED bulb and TV converts AC to DC internally, because electronics run on DC. Solar panels and batteries produce DC too, which is why solar systems need an inverter to produce AC for the home.

Step 5 of 13Explore

Watch alternating current reverse

US outlets are "120 V", but that is an average (RMS) value. The voltage actually swings between about +170 V and −170 V, 60 times a second. Move the sliders to compare 60 Hz and 50 Hz, or 120 V and 230 V systems.

-2000200 01020304050
RMS ("nameplate") voltage
120 V
One full cycle takes
16.7 ms
Direction reversals per second
120

Step 6 of 13Practice · Choose one

What was the main reason AC became the standard for power grids?

Step 7 of 13Learn

120 and 240 volts in a US home

US homes get both 120 V and 240 V from the same service, using a clever arrangement called split-phase power.

The service transformer's output winding has a connection at its center. Three wires come into the home:

  • Two hot wires, often called legs or lines, each carrying 120 V relative to the center.
  • One neutral wire, connected to the center tap and to ground.

The two hot legs are opposite in phase: when one is at +170 volts peak, the other is at −170. So:

  • Between either hot leg and neutral, you get 120 V, used for ordinary outlets and lights.
  • Between the two hot legs, you get 240 V, used for electric dryers, ranges, water heaters, central air conditioners, well pumps and EV chargers.

In the service panel, the breakers alternate between the two legs. A single-pole breaker connects to one leg and feeds a 120 V circuit. A double-pole breaker, twice as wide, connects to both legs and feeds a 240 V circuit.

The size of the overall service, usually 100 to 200 amps for typical homes (some older homes have 60 A, larger homes may have more), sets how much total power the home can draw at once. A 200 A service at 240 V can supply up to 48,000 watts in theory.

Most other countries use a single hot wire at 220 to 240 V for everything, with three-phase power sometimes supplied for larger homes.

Step 8 of 13Compare

120 V and 240 V circuits in a US home

Aspect120 V circuits240 V circuits
Wires usedOne hot leg + neutralBoth hot legs (sometimes + neutral)
BreakerSingle-pole (one slot)Double-pole (two slots, joined handle)
Typical loadsLights, outlets, TVs, small appliancesDryers, ranges, water heaters, central AC, EV chargers
WhyEnough for everyday devicesSame power at half the current, so thinner wire than 120 V would need

Step 9 of 13Practice · Fill in the blanks

Fill in the blanks

In a US split-phase system, the voltage between one hot leg and neutral is volts, and the voltage between the two hot legs is volts.

Step 10 of 13Note

Step 11 of 13Practice · Chart

A hot summer day on the grid

When would a time-of-use plan most likely charge the highest price?

Tap the point that answers the question, then press Check.

A hot summer day on the gridLine chart with 8 categories: 12 am: 62%; 3 am: 55%; 6 am: 60%; 9 am: 72%; 12 pm: 85%; 3 pm: 96%; 6 pm: 100%; 9 pm: 82%.0%20%40%60%80%100%Share of peak demand12 am3 am6 am9 am12 pm3 pm6 pm9 pm
Illustrative shape of a summer demand curve; real curves vary by region and season.
A hot summer day on the grid
ItemDemand
12 am62%
3 am55%
6 am60%
9 am72%
12 pm85%
3 pm96%
6 pm100%
9 pm82%

Step 12 of 13Practice · True or false

A double-pole breaker in a US panel is used to feed a 240-volt circuit.

Step 13 of 13Practice · Choose one

Why do power companies transmit electricity over long distances at very high voltages?