Find a course

Module 2: The Home Electrical SystemLesson 5 of 1312 min

Wires, Colors and Wire Gauges

Learn what hot, neutral and ground wires do, what their colors mean in the US and elsewhere, and how wire gauge limits the current a circuit can carry.

Step 1 of 11Learn

Three wires, three jobs

Open a typical modern US outlet box (which you should leave to an electrician) and you'd find a cable containing three wires, each with a distinct job.

  • Hot wire: usually black insulation, sometimes red (in 240 V circuits or for a second hot conductor). It carries voltage from the breaker to the device. It's the dangerous one: touching it while touching ground completes a circuit through you.
  • Neutral wire: usually white (or gray). It carries current back to the panel under normal operation, completing the circuit. Neutral is connected to ground at the main panel, so it's normally near 0 volts, but it carries current whenever the circuit is in use and can still shock you, especially if something is wired wrong.
  • Ground wire: bare copper or green. It normally carries no current. It's a safety path that connects metal boxes, appliance cases and the ground pin of outlets back to the panel and to the earth. If a hot wire accidentally touches a metal case, the ground wire carries a large fault current back to the panel, tripping the breaker instead of leaving the case live.

Color conventions differ around the world. In much of Europe and many other countries using IEC standards, brown is live (hot), blue is neutral and green-and-yellow stripes mark the earth (ground) wire. Older installations may use different colors entirely, and colors in existing wiring aren't a guarantee; a previous owner may have miswired something. Professionals always test before touching.

Step 2 of 11Compare

Common wire color codes

AspectUS (typical)Europe and many IEC countries
Hot / liveBlack, or red for a second hotBrown (also black or gray for other phases)
NeutralWhite or grayBlue
Ground / earthBare copper or greenGreen with yellow stripes
Typical outlet voltage120 V220 to 240 V

Step 3 of 11Practice · Choose one

In a standard US cable, what is the main job of the bare copper or green wire?

Step 4 of 11Diagram

Inside a 14/2 cable

Inside a 14/2 cableParts diagram: NM cable "14/2 with ground", Black: hot, White: neutral, Bare copper: ground, Outer jacket, "14/2": the code.NM cable"14/2 withground"Black: hotWhite: neutralBare copper:groundOuter jacket"14/2": thecode

Tap a shape with to see more.

NM cable "14/2 with ground"
Black: hot

Carries current from the breaker to the load.

White: neutral

Carries current back to the panel. It normally carries as much current as the hot.

Bare copper: ground

Carries no current normally; it provides a fault path that trips the breaker.

Outer jacket

Plastic sheath that protects the wires. Its color often hints at the gauge (white is commonly 14 AWG, yellow 12 AWG).

"14/2": the code

14 = wire gauge, 2 = number of insulated conductors, plus a bare ground.

Step 5 of 11Learn

Wire gauge: thicker carries more

Wires are sized by their gauge. In North America the American Wire Gauge (AWG) system is used, and it runs backward: a smaller number means a thicker wire. Elsewhere, wire is usually sized by its cross-sectional area in square millimeters (mm²).

A thicker wire has lower resistance, so it heats less when carrying current. Since heat in a wire rises with the square of the current (P = I2 × R), each wire size has a maximum safe current, its ampacity.

Typical US residential copper wiring:

Wire gaugeTypical breakerCommon uses
14 AWG15 AGeneral lighting and outlet circuits
12 AWG20 AKitchen, bathroom, laundry and garage outlets
10 AWG30 AElectric dryers, water heaters, some air conditioners
8 AWG40 ARanges, some EV chargers
6 AWG50 to 60 ARanges, larger EV chargers, subpanels

The breaker must be matched to the wire: never larger than the wire's rating. A 20 A breaker on 14 AWG wire is a classic fire hazard.

Longer runs cause voltage drop: the wire's resistance consumes some of the voltage along the way. Over long distances, such as to a detached garage, electricians use a larger wire than the minimum to keep voltage drop small.

Some homes built in the US in the mid-1960s to early 1970s have aluminum branch wiring. Aluminum expands and oxidizes differently from copper, and connections can loosen and overheat. If your home has it, have a qualified electrician evaluate the connections.

Step 6 of 11Practice · Chart

Copper wire gauge and typical breaker size

Which wire would an electrician use for a 30 A dryer circuit?

Tap the bar that answers the question, then press Check.

Copper wire gauge and typical breaker sizeBar chart with 5 categories: 14 AWG: 15 A; 12 AWG: 20 A; 10 AWG: 30 A; 8 AWG: 40 A; 6 AWG: 55 A.0 A20 A40 A60 AAmps14 AWG12 AWG10 AWG8 AWG6 AWG15 A20 A30 A40 A55 A
Common US values for copper NM cable; exact limits depend on cable type, insulation and local code.
Copper wire gauge and typical breaker size
ItemTypical maximum breaker
14 AWG15 A
12 AWG20 A
10 AWG30 A
8 AWG40 A
6 AWG55 A

Step 7 of 11Practice · Fill in the blanks

Fill in the blanks

In the American Wire Gauge system, a gauge number means a thicker wire. Standard 15-amp circuits use AWG copper wire, while 20-amp circuits use AWG.

Step 8 of 11Try the calculator

Voltage drop estimator

A simplified estimate for a 120 V copper circuit. Resistance per 1,000 ft of copper (one conductor): 14 AWG ≈ 2.5 Ω, 12 AWG ≈ 1.6 Ω, 10 AWG ≈ 1.0 Ω. Current travels out and back, so the loop is twice the one-way length.

Voltage drop
3.84 V
Voltage drop as a share of 120 V
3.2 %
Heat lost in the wires
46 W

Step 9 of 11Note

Step 10 of 11Practice · True or false

A 12 AWG wire is thinner than a 14 AWG wire.

Step 11 of 11Practice · What would you do?

What would you do?

A homeowner notices that a 20 A breaker protects a bedroom circuit, but the wire at the panel is labeled 14 AWG. What does this suggest?