Calculating Circuit Loads
Add up appliance loads, apply the 80% rule for continuous loads, and plan where to plug in high-power devices so circuits are not overloaded.
Welcome back!
Step 1 of 12Learn
How much can a circuit carry?
Every branch circuit has a limit set by its breaker and wire: commonly 15 A or 20 A for 120 V outlet circuits in US homes. The maximum power follows directly from P = V × I:
- 15 A × 120 V = 1,800 W
- 20 A × 120 V = 2,400 W
But you shouldn't plan to run a circuit at its maximum. For continuous loads, those that run for three hours or more, such as space heaters, EV chargers and some lighting, the US electrical code limits the load to 80% of the circuit rating:
- 80% of 15 A = 12 A, or 1,440 W
- 80% of 20 A = 16 A, or 1,920 W
A single 1,500 W space heater running all evening nearly fills a 15 A circuit on its own. Add a TV, lamps and a laptop and you're over the continuous limit.
Here are typical power draws to help you estimate:
| Appliance | Typical power |
|---|---|
| LED bulb | 5 to 15 W |
| Laptop | 30 to 100 W |
| TV | 50 to 200 W |
| Refrigerator (running) | 100 to 250 W |
| Microwave | 1,000 to 1,500 W |
| Hair dryer | 1,200 to 1,875 W |
| Space heater | about 1,500 W |
| Toaster or kettle | 1,000 to 1,500 W |
Heating appliances are the usual culprits. Anything whose job is to make heat tends to draw 1,000 W or more.
Step 2 of 12Practice · Work it out
What is the maximum continuous load, in watts, for a 20 A, 120 V circuit under the 80% rule?
Step 3 of 12Chart
Maximum vs continuous load
Step 4 of 12Try the calculator
Circuit load planner
Add the wattage of everything that may run at the same time on one circuit. The 80% line is the guideline for loads that run three hours or more.
- Total load
- 1,710 W
- Current
- 14.3 A
- Share of breaker rating
- 95 %
- 80% continuous limit
- 1,440 W
Step 5 of 12Learn
Finding which outlets share a circuit
To spread loads, you need to know which outlets share a circuit, and it's often not obvious. Circuits frequently cross room boundaries. One bedroom circuit might include outlets in the hallway and the next bedroom; a kitchen might have several circuits, with alternate countertop outlets on different ones.
Ways to find out:
- Use the panel directory, if it's accurate.
- Map it yourself with a helper: plug a lamp or radio into each outlet, switch off one breaker at a time and note what goes dead.
- Use a circuit breaker finder, an inexpensive tool with a transmitter you plug into an outlet and a receiver you pass over the breakers to identify the matching one.
Once you know your circuits, you can plan:
- Put heavy hitters such as space heaters, window air conditioners and hair dryers on different circuits from each other.
- In the kitchen, spread the toaster, kettle, microwave and air fryer across the separate countertop circuits.
- Keep the refrigerator on its own circuit if possible, so an overload elsewhere doesn't shut it off.
- If you regularly trip breakers in one area, it's a sign the area needs an additional circuit, which a licensed electrician can add.
Large appliances usually have dedicated circuits: a circuit that serves only that appliance. Examples include the range, dryer, water heater, furnace, central air conditioner, dishwasher, garbage disposal, microwave and often the refrigerator. Their breakers and wire are sized specifically for them.
Step 6 of 12Practice · What would you do?
What would you do?
On winter mornings, the breaker for Sam's bathroom trips when he uses his 1,875 W hair dryer while a 1,500 W space heater runs in the same bathroom. The circuit is 20 A at 120 V. What is the best solution?
Step 7 of 12Practice · Diagram
Sam's bathroom circuit (20 A, 120 V)
Which load is the one that trips the breaker?
Tap the shape that answers the question, then press Check.
- Heater alone
1,500 W
- Hair dryer alone
1,875 W
- Both together
1,875 + 1,500 = 3,375 W, about 28 A.
Step 8 of 12Note
Step 9 of 12Chart
A motor starting up
| Item | Current |
|---|---|
| 0 s | 30 A |
| 0.1 s | 24 A |
| 0.2 s | 14 A |
| 0.3 s | 8 A |
| 0.5 s | 6 A |
| 1 s | 6 A |
| 2 s | 6 A |
Step 10 of 12Practice · Select all that apply
Which appliances commonly need dedicated circuits? Select all that apply.
Select all that apply.
Step 11 of 12Practice · True or false
A 15 A, 120 V circuit can safely run a 1,500 W space heater plus a 1,000 W microwave at the same time.
Step 12 of 12Practice · Choose one
What does the 80% rule for continuous loads mean for a 15 A circuit at 120 V?
Lesson complete!