How Heat Moves Through a House
Learn conduction, convection and radiation, understand R-value and U-factor, and calculate heat loss through a wall or ceiling with a simple formula.
Welcome back!
Step 1 of 11Learn
Heat always flows downhill
Heat always flows from warmer places to cooler ones. In winter, it flows out of your house; in summer, it flows in. A furnace or air conditioner does not "make" a house comfortable so much as replace heat as fast as the building leaks it (or remove heat as fast as it enters). Slow the leak and the equipment works less.
Heat moves in three ways:
- Conduction: heat flowing through a solid material, molecule to molecule. A metal spoon in hot soup gets hot along its handle. In a house, heat conducts through walls, ceilings, floors, windows and especially through wood or metal framing, which conducts heat much faster than insulation. These paths are called thermal bridges.
- Convection: heat carried by moving air or liquid. Warm air rises, cools and sinks, setting up currents inside rooms and wall cavities. Leaky homes lose huge amounts of heat by air leakage, warm air escaping through gaps and cold air entering to replace it. Air leakage is often responsible for a quarter to a third or more of heating and cooling losses.
- Radiation: heat traveling as infrared energy from a warm surface to a cooler one, with no air needed. You feel it standing near a cold window in winter (your body radiates heat to the cold glass) or from sunlight through a window in summer.
Effective efficiency work addresses all three: insulation slows conduction, air sealing stops convective leakage, and low-emissivity window coatings and radiant barriers reduce radiation.
Step 2 of 11Practice · Match the pairs
Match each example to the type of heat transfer it shows.
Tap an answer, then tap the place where it belongs (or drag it there).
- Heat passing through a wooden wall stud
- Warm air escaping through a gap around an attic hatch
- Feeling chilly near a cold window even with no draft
Step 3 of 11Tap to reveal
Thermal bridges you can find in most houses
Wall studs
Wood framing typically makes up 15–25% of a wall's area and conducts heat about three to four times faster than the insulation between it, lowering the whole wall's effective R-value well below the label on the batts.
Concrete slab edges and foundations
Exposed slab edges and uninsulated basement walls conduct heat straight to the cold ground and outdoor air.
Window and door frames
Aluminum frames without thermal breaks conduct heat very quickly; vinyl, wood and fiberglass frames do much better.
Balconies and steel beams
In apartment buildings, concrete balconies that extend from inside floors act like cooling fins, a major heat loss in older buildings.
Step 4 of 11Learn
R-value and U-factor
R-value measures a material's resistance to conductive heat flow. The higher the R-value, the better it insulates. In the US, R-values use units of ft²·°F·h/BTU; most countries use metric RSI values (m²K/W), where R-1 US equals about RSI 0.176.
Typical R-values per inch:
- Fiberglass or mineral wool batts: about R-3 to R-4.3 per inch.
- Blown cellulose: about R-3.2 to R-3.8 per inch.
- Rigid foam boards: about R-4 to R-6.5 per inch.
- Closed-cell spray foam: about R-6 to R-7 per inch.
- Wood: about R-1 per inch.
- A single pane of glass: about R-1 in total.
R-values of layers add up: R-13 batts in a wall plus R-5 foam sheathing give roughly R-18 (ignoring framing).
U-factor (or U-value) is the inverse of R: it measures how readily heat flows through. U = 1 ÷ R. Lower U-factor means better insulation. U-factors are used mainly for windows and whole assemblies. A single-pane window has a U-factor around 1.0; a good double-pane low-e window about 0.25–0.30; a triple-pane window about 0.15–0.20.
Heat loss through a surface by conduction is:
Heat loss (BTU per hour) = Area (ft²) × temperature difference (°F) ÷ R
or equivalently Area × ΔT × U.
Notice that doubling the R-value halves the heat loss, but each additional R saves less than the last. Going from R-1 to R-11 cuts loss by 91%; going from R-30 to R-60 cuts the remaining loss by half, a much smaller absolute amount.
Step 5 of 11Try the calculator
Heat loss through a ceiling or wall
Heat loss (BTU/h) = area × temperature difference ÷ R-value. Compare a poorly insulated attic floor with an upgraded one.
- Heat loss before
- 3,636 BTU/h
- Heat loss after
- 816 BTU/h
- Reduction
- 77.6 %
Step 6 of 11Practice · Work it out
A 1,200 ft² attic floor has R-12 insulation. Inside is 70 °F and outside is 30 °F. How many BTU per hour are lost through it by conduction?
Step 7 of 11Explore
Diminishing returns of insulation
Heat loss through 1,000 ft² with a 40 °F temperature difference, as R-value increases. Each extra R saves less than the one before.
- Loss at R-11
- 3,636 BTU/h
- Loss at R-30
- 1,333 BTU/h
- Loss at R-60
- 667 BTU/h
Step 8 of 11Learn
Degree days and climate
How much a given improvement saves depends on your climate. Engineers measure how cold a winter is using heating degree days (HDD). For each day, subtract the day's average temperature from 65 °F (the usual base, because homes with internal heat from people and appliances typically need no heating above that). A day averaging 35 °F counts as 30 degree days; a day averaging 70 °F counts as zero. Add up the year.
Typical annual heating degree days: around 1,500 in Houston, 4,500 in Washington, DC, 6,500 in Chicago and 9,000 or more in Fargo, North Dakota. Cooling degree days (CDD) measure summer heat the same way, above 65 °F.
Yearly conductive heat loss through a surface can be estimated as:
Annual BTU ≈ Area × HDD × 24 ÷ R
For 1,000 ft² of attic at R-11 in Chicago: 1,000 × 6,500 × 24 ÷ 11 ≈ 14.2 million BTU a year, or about 142 therms of heat. At R-49 it drops to about 32 therms. With a 95% efficient gas furnace and gas at $1.50 per therm, the upgrade saves about (142 − 32) ÷ 0.95 × $1.50 ≈ $170 a year from conduction alone, before counting the air sealing that usually comes with attic work.
The US Department of Energy and ENERGY STAR publish recommended insulation levels by climate zone. For attics, recommendations range from about R-30 in the warmest zones to R-49 to R-60 in cold zones. Many older homes have R-19 or less.
Step 9 of 11Practice · Choose one
Why does adding insulation save more money in Minneapolis than in Atlanta, for the same house?
Step 10 of 11Practice · True or false
Going from R-30 to R-60 in an attic saves more energy than going from R-0 to R-30.
Step 11 of 11Practice · Fill in the blanks
Fill in the blanks
R-values of insulation layers in an assembly . The U-factor equals 1 divided by the .