Find a course

Module 3: Heating, Cooling and Hot WaterLesson 6 of 1014 min

Water Heating

Compare tank, tankless and heat pump water heaters, calculate the energy in a hot shower, and cut hot water use with simple fixes.

Step 1 of 12Learn

The second-biggest energy user

Water heating is often the second-largest energy use in a home, typically around 15–20% of total energy. A family of four can easily use 60 gallons (about 230 liters) of hot water a day for showers, laundry, dishes and sinks.

Heating water takes a lot of energy because water has a high specific heat: it takes about 8.34 BTU to raise one gallon of water by 1 °F (or about 4.2 kJ to raise one liter by 1 °C).

Energy to heat water (BTU) = gallons × 8.34 × temperature rise (°F)

A 10-minute shower with a 2.5-gallon-per-minute showerhead uses 25 gallons. If the water heater raises the temperature from 55 °F to 105 °F at the showerhead, a rise of 50 °F, that takes 25 × 8.34 × 50 = 10,425 BTU, about 3.1 kWh of heat. With an electric resistance water heater at 95% efficiency, that is about 3.2 kWh of electricity per shower, or roughly 50 cents at $0.16/kWh. A family taking four such showers a day spends around $700 a year on shower hot water alone.

Three levers control water heating costs:

  1. Use less hot water: efficient showerheads and faucets, shorter showers, cold-water laundry, full dishwasher loads.
  2. Lower the temperature: many heaters are set to 140 °F at the factory; 120 °F (49 °C) is usually enough and reduces scalding risk and standby losses.
  3. Use a more efficient water heater, especially a heat pump water heater.

Step 2 of 12Try the calculator

Shower energy and cost

Energy (BTU) = gallons × 8.34 × temperature rise. Compare showerheads and shower lengths.

Hot water used
25 gallons
Heat energy
3.06 kWh
Electricity used
3.29 kWh
Cost per shower
0.53 $

Step 3 of 12Practice · Work it out

A bath uses 40 gallons of water heated from 50 °F to 110 °F. How many BTU of heat does that take? (Use 8.34 BTU per gallon per °F.)

Step 4 of 12Learn

Types of water heaters

Water heaters are rated by Uniform Energy Factor (UEF): the share of energy input that ends up as hot water used, over a standard test. Higher is better, and heat pumps can exceed 1.

  • Storage tank, gas: heats a 30–80 gallon tank with a burner. UEF around 0.6–0.7 for standard models, up to about 0.8–0.9 for condensing models. Loses heat continually through the tank walls and flue, called standby loss.
  • Storage tank, electric resistance: heating elements in the tank. UEF around 0.9–0.95, because there is no flue, but electricity usually costs more per unit of energy than gas.
  • Tankless (on-demand): heats water only as it flows, avoiding standby losses. Gas models reach UEF around 0.8–0.95. They provide endless hot water but have flow limits, cost more to install and may need larger gas lines; electric tankless units can require very large electrical circuits.
  • Heat pump water heater (HPWH): a small heat pump on top of a tank pulls heat from the surrounding air into the water. UEF around 3–4, so it uses roughly 60–75% less electricity than a standard electric water heater. It cools and dehumidifies the space it sits in, which is helpful in a hot garage or basement and less welcome in a cold room in winter. It also needs space and air volume around it and usually runs more quietly than people expect.
  • Solar water heating: collectors heat water directly, with a backup heater for cloudy periods.

A water heater typically lasts 10–15 years. Because most are replaced in an emergency when they leak, many households end up with whatever the plumber has on the truck. Planning the next one before the old one fails is one of the easiest efficiency wins.

Step 5 of 12Note

Step 6 of 12Compare

Water heater options compared

AspectGas tankElectric tankGas tanklessHeat pump water heater
Typical UEFAbout 0.6–0.7 (condensing up to about 0.9)About 0.9–0.95About 0.8–0.95About 3–4
Standby lossesYesYes, smallerAlmost noneYes, small
Running costModerateHighest in most areasModerate to lowLowest in most areas
Installation notesNeeds ventingSimpleNeeds venting, larger gas lineNeeds space, air and a nearby drain

Step 7 of 12Practice · Work it out

An electric resistance water heater (UEF 0.92) uses 3,500 kWh a year. A heat pump water heater with a UEF of 3.5 would deliver the same hot water. About how many kWh a year would it use? Round to the nearest 10 kWh.

Step 8 of 12Practice · Chart

Uniform Energy Factor by water heater type

Which type needs the least energy for the same hot water?

Tap the bar that answers the question, then press Check.

Uniform Energy Factor by water heater typeBar chart with 5 categories: Gas tank, standard: 0.62; Gas tank, condensing: 0.85; Electric resistance tank: 0.92; Gas tankless: 0.93; Heat pump water heater: 3.5.01234Gas tank, standard0.62Gas tank, condensing0.85Electric resistance tank0.92Gas tankless0.93Heat pump water heater3.5UEF (higher is better)
Typical values for new US models; check the EnergyGuide label for a specific unit.
Uniform Energy Factor by water heater type
UEF (higher is better)UEF
Gas tank, standard0.62
Gas tank, condensing0.85
Electric resistance tank0.92
Gas tankless0.93
Heat pump water heater3.5

Step 9 of 12Learn

Cutting hot water use

The cheapest hot water is the hot water you don't use. Simple, low-cost measures:

  • Efficient showerheads: federal law caps showerheads at 2.5 gallons per minute, and WaterSense-labeled models use 2.0 gpm or less, with many good ones at 1.5–1.8 gpm. Going from 2.5 to 1.75 gpm saves 30% of shower hot water with little difference in feel for many people.
  • Faucet aerators: about 1.0–1.5 gpm for bathroom sinks.
  • Cold-water laundry: around 90% of the energy a washing machine uses goes to heating water. Modern detergents clean well in cold water for most loads.
  • Full dishwasher loads: a modern ENERGY STAR dishwasher typically uses less water than washing the same dishes by hand under a running tap. Skip the pre-rinse; scrape instead.
  • Fix leaks: a hot water faucet dripping once per second wastes over 3,000 gallons a year.
  • Insulate hot water pipes where accessible, especially the first few feet from the heater, and consider an insulating blanket on older tanks if the manufacturer allows.
  • Set the temperature to 120 °F (49 °C). Each 10 °F reduction typically saves around 3–5% of water heating energy. People with weakened immune systems, or homes with dishwashers lacking a booster heater, should follow medical or manufacturer guidance; some experts recommend storing water at 140 °F with mixing valves to control Legionella risk.

These steps also reduce the size of water heater a household needs, which matters if switching to a heat pump water heater.

Step 10 of 12Practice · Select all that apply

Which actions reduce hot water energy use? Select all that apply.

Select all that apply.

Step 11 of 12Note

Step 12 of 12Practice · True or false

Washing a load of laundry in cold water instead of hot saves energy mainly because the washing machine motor runs less.