How Solar Cells Work
See how silicon cells turn light into electricity, how cells become panels, what panel ratings and efficiency mean, and how heat affects output.
Welcome back!
Step 1 of 13Learn
Light in, electrons out
In 1839, a 19-year-old French physicist, Edmond Becquerel, noticed that certain materials produced a small electric current when exposed to light. This photovoltaic effect, from "photo" (light) and "volt" (electricity), is what every solar panel uses today.
Most solar cells are made of silicon, the second most common element in Earth's crust, purified and sliced into thin wafers. Pure silicon is not very useful on its own, so manufacturers add tiny amounts of other elements, a process called doping:
- Adding phosphorus creates n-type silicon, with extra free electrons (negative).
- Adding boron creates p-type silicon, with "holes" where electrons are missing (positive).
Where the two layers meet, at the p-n junction, a built-in electric field forms. When a particle of light, called a photon, with enough energy strikes the silicon, it knocks an electron loose. The junction's electric field pushes freed electrons toward the n-side and holes toward the p-side. Connect the two sides with a wire, and electrons flow through it: that flow is an electric current that can power a light, charge a battery or feed the grid.
Thin metal lines on the front of the cell collect the current while letting most light pass. An anti-reflective coating, which gives cells their dark blue or black color, helps them absorb more light.
A single silicon cell produces only about 0.5–0.6 volts, so cells are wired together in series to build up useful voltages.
Step 2 of 13Practice · Put in order
Put the steps of the photovoltaic effect in order.
Drag the items, or use the arrow buttons, to put them in order.
- The photon's energy frees an electron
- The electric field at the p-n junction pushes the electron to one side
- Electrons flow through an external wire as current
- A photon of sunlight strikes the silicon cell
- The current powers a device or feeds an inverter
Step 3 of 13Learn
From cells to panels to arrays
Solar equipment is built in layers:
- A cell is a single wafer of silicon, about 15–21 cm on a side.
- A module, or panel, contains many cells, typically 54, 60, 66 or 72 full cells, or twice as many half-cut cells, wired in series, sealed behind tempered glass, backed with a protective sheet and framed in aluminum. Today's residential panels are commonly rated around 400–450 watts and measure roughly 1.7–2 square meters.
- An array is a group of panels wired together on a roof or ground mount.
Panels are rated under standard test conditions (STC): 1,000 W/m² of sunlight, a cell temperature of 25 °C and a specified light spectrum. A "400 W" panel produces about 400 W under those exact conditions. In real life, cells are usually hotter than 25 °C and sunlight is often weaker, so panels typically produce less than their rating, even at noon.
Panel efficiency is the share of the sunlight hitting a panel that it converts into electricity:
Efficiency = rated power ÷ (area × 1,000 W/m²)
A 400 W panel with an area of 1.9 m² has an efficiency of 400 ÷ 1,900 = 21%. Most mainstream panels today are about 20–23% efficient. Higher efficiency means more watts from the same area, which matters most on small roofs. On large roofs or ground mounts, cost per watt matters more than efficiency.
Step 4 of 13Practice · Diagram
Building blocks of a solar system
Each level is made of many units of the level below it.
Which level is rated at about 400–450 watts?
Tap the shape that answers the question, then press Check.
- Cell
One silicon wafer, about 15–21 cm on a side, producing a few watts.
- Module (panel)
Dozens of cells wired in series behind glass, typically 400–450 W.
- Array
A group of panels on a roof or ground mount, wired together to an inverter.
Step 5 of 13Practice · Work it out
A solar panel is rated 420 W and has an area of 2.0 square meters. What is its efficiency, in percent?
Step 6 of 13Learn
Types of solar cells
Several cell technologies compete:
- Monocrystalline silicon: cut from a single crystal, uniform black color, efficiency typically 20–23% for mainstream panels. It now dominates the market. Newer cell designs with names like PERC, TOPCon and heterojunction (HJT) have steadily pushed efficiency higher.
- Polycrystalline silicon: made from many crystal fragments, blue speckled look, slightly lower efficiency (around 15–18%). Once common because it was cheaper, it has largely disappeared from new installations.
- Thin film: very thin layers of materials such as cadmium telluride (CdTe) deposited on glass. Efficiency is somewhat lower than mono silicon, but it performs well in heat and is used in many large utility-scale plants.
- Bifacial panels: capture light on both sides, gaining extra energy from light reflected off the ground. They are common in ground-mounted systems over light-colored surfaces.
- Perovskites and tandem cells: an emerging technology. Stacking a perovskite layer on top of silicon has produced laboratory efficiencies above 30%. Durability is the main challenge before mass adoption.
Why can't panels be 100% efficient? Photons with too little energy pass straight through without freeing electrons, and photons with too much energy waste the excess as heat. For a single-junction silicon cell, physics limits efficiency to about 30%, called the Shockley-Queisser limit. Tandem cells beat it by stacking materials that capture different colors of light.
Step 7 of 13Practice · Match the pairs
Match each cell technology to its description.
Tap an answer, then tap the place where it belongs (or drag it there).
- Monocrystalline silicon
- Polycrystalline silicon
- Thin film (CdTe)
- Bifacial
- Perovskite tandem
Step 8 of 13Chart
Typical efficiency by cell technology
Step 9 of 13Note
Step 10 of 13Learn
Heat, real-world output and degradation
Two factors make real-world output lower than the label: heat and aging.
Heat. Solar cells lose efficiency as they warm. Each panel has a temperature coefficient of power, typically around −0.3% to −0.4% per °C above 25 °C. On a hot summer day, cells can easily reach 60 °C or more, 35 °C above the test temperature. With a coefficient of −0.35%/°C, output drops by about 35 × 0.35 = 12%. That is why spring often brings the highest peaks, and why mounting panels with an air gap for ventilation helps.
Degradation. Panels slowly produce less as they age. Good modern panels lose about 0.3–0.5% of output per year. Most manufacturers offer a performance warranty guaranteeing around 80–90% of the original output after 25 or 30 years, along with a separate product warranty covering defects for 10–25 years. A panel losing 0.5% a year still delivers about 88% of its original power after 25 years, and panels often keep working well beyond 30 years.
Real-world output. Combining heat, dust, wiring and inverter losses, typical systems deliver roughly 75–85% of what their panel ratings multiplied by peak sun hours would suggest. This ratio is called the performance ratio, and you'll use it in the sizing lessons.
Daily production estimate:
Energy (kWh/day) ≈ system size (kW) × peak sun hours × performance ratio
A 6 kW system with 4.5 peak sun hours and a performance ratio of 0.8 makes about 6 × 4.5 × 0.8 = 21.6 kWh per day.
Step 11 of 13Try the calculator
Heat loss calculator
Estimate how much power a panel loses on a hot day using its temperature coefficient.
- Change in output
- -10.5 %
- Power at that temperature (full sun)
- 358 W
Step 12 of 13Practice · Work it out
A 400 W panel has a temperature coefficient of −0.4%/°C. On a hot day its cells reach 65 °C in full sun. About how many watts does it produce? (Assume all other conditions match the test.)
Step 13 of 13Practice · True or false
A good solar panel loses about half of its output within its first 10 years.
Lesson complete!