Inverters, Batteries and the Grid
Compare string inverters, microinverters and optimizers, understand grid-tied, off-grid and hybrid systems, and learn how net metering credits your exports.
Welcome back!
Step 1 of 13Learn
Why a system that makes power can go dark
In 2020 and 2021, many homeowners with rooftop solar were surprised during power outages: the sun was shining, but their lights went out with everyone else's. Their systems were working exactly as designed.
Most home solar systems are grid-tied: they connect to the utility grid and have no battery. When the grid goes down, their inverters automatically shut off within seconds. This is called anti-islanding protection, and it exists to protect utility line workers, who could be electrocuted if rooftop systems kept energizing lines they believe are dead. Grid-tied systems without batteries therefore provide no backup power in an outage.
There are three basic system types:
- Grid-tied: the most common and cheapest. The home uses solar power when available, draws from the grid when needed and exports surplus to the grid.
- Grid-tied with battery (hybrid): adds a battery that stores surplus solar for evening use and can power selected circuits during outages, using equipment that safely disconnects the home from the grid first.
- Off-grid: no utility connection at all. Requires a large battery bank, careful sizing for the worst winter weeks and usually a backup generator. Common for remote cabins, farms and places without grid access, and expensive per kWh compared with grid-tied systems.
Before buying, decide what you want: lowest cost per kWh, backup during outages or full independence. Each choice leads to a different system.
Step 2 of 13Practice · Choose one
A grid-tied solar home with no battery loses grid power on a sunny afternoon. What happens to its solar system?
Step 3 of 13Practice · Diagram
How power flows in a grid-tied home
Which step stops working when the grid goes down, cutting off a home with no battery?
Tap the shape that answers the question, then press Check.
- Panels make DC
Sunlight frees electrons in the cells, producing direct current.
- Inverter turns it into AC
It matches the grid's voltage and frequency, and shuts down if the grid goes dark.
- Home electrical panel
Solar power goes to the home's circuits first.
- Appliances use it
Lights, fridge and outlets draw solar power while it is available.
- Surplus to the grid
Extra power flows out through the meter; at night, power flows back in.
Step 4 of 13Learn
Inverters: the brain of the system
Solar panels produce direct current (DC). Homes and the grid use alternating current (AC). The inverter converts DC to AC, matches the grid's voltage and frequency, and continuously adjusts the panels' operating point to extract maximum power, a function called maximum power point tracking (MPPT). Modern inverters convert about 96–98% of the DC power into AC.
There are three main architectures:
- String inverter: panels are wired in series into one or more strings feeding a single central inverter, usually mounted near the electrical panel or in the garage. It is the cheapest option and easy to service, but in a series string, a shaded or failing panel can drag down the output of the whole string, like a kink in a garden hose. String inverters typically last 10–15 years, so plan for one replacement over the system's life.
- Microinverters: a small inverter under each panel converts DC to AC right on the roof. Each panel works independently, so shading on one panel does not affect the others, and you can monitor each panel. They cost more, but warranties often run 25 years.
- Power optimizers: DC devices under each panel that optimize each panel individually, then send the power to a central string inverter. They offer much of the shade tolerance and panel-level monitoring of microinverters at a cost in between.
Rapid shutdown rules in the US electrical code require rooftop systems to reduce voltage on the roof quickly in an emergency so firefighters can work safely. Microinverters and optimizers make compliance straightforward.
Step 5 of 13Compare
Inverter options compared
| Aspect | String inverter | Microinverters | String inverter with optimizers |
|---|---|---|---|
| Where conversion happens | One central unit | Under each panel | Optimized at each panel, converted centrally |
| Shade tolerance | Low: one weak panel affects the string | High: each panel independent | High |
| Monitoring | System or string level | Panel level | Panel level |
| Typical cost | Lowest | Highest | Middle |
| Best for | Simple, unshaded roofs | Complex or partly shaded roofs | Mixed roofs wanting a central inverter |
Step 6 of 13Practice · Sort into groups
Which inverter approach is the better fit for each roof?
Tap an item, then tap its group (or drag it there).
Step 7 of 13Learn
Batteries and backup
Home batteries, typically 10–15 kWh of usable capacity per unit, store surplus solar for later. Like grid batteries, they have two key ratings:
- Usable energy (kWh): how much they can store.
- Power (kW): how much they can deliver at once, often 5–11.5 kW per unit. Starting a central air conditioner or well pump can need a brief surge above the normal rating.
Most home batteries use lithium iron phosphate (LFP) chemistry, which is long-lasting and less prone to overheating than older lithium chemistries. Warranties commonly cover 10 years with a minimum remaining capacity, often around 70%.
How long will a battery keep the lights on? Divide usable energy by the load. A 13.5 kWh battery running essential loads of 1 kW (refrigerator, lights, internet, a few outlets) lasts about 13 hours, longer if solar recharges it during the day. Running a 4 kW air conditioner and an electric range drains it in a few hours. Backup systems usually power a critical loads panel rather than the whole house.
A battery's financial value depends on local rules. Where utilities pay much less for exported solar than they charge for imported electricity, or where time-of-use rates make evening power expensive, a battery lets you store midday solar and use it in the evening, saving money. Where net metering credits exports at full retail value, the grid acts like a free battery, and a home battery is mostly about backup.
Step 8 of 13Practice · Work it out
A home battery has 13.5 kWh of usable capacity. During an outage at night, the critical loads average 0.9 kW. About how many hours can the battery supply them?
Step 9 of 13Practice · Chart
How long a 13.5 kWh battery lasts
Runtime = usable energy ÷ load, with no solar recharge.
Tap the load that drains the battery in less than 4 hours.
Tap the bar that answers the question, then press Check.
Step 10 of 13Learn
Net metering and net billing
How your utility credits the solar power you send to the grid has a huge effect on a system's value.
Net metering (net energy metering, NEM) is the simplest arrangement. Your meter effectively runs backward when you export. Each kWh you send to the grid offsets a kWh you take later at the same retail price. You pay only for your net consumption over the billing period. Many US states adopted net metering when rooftop solar was rare.
Net billing pays a lower rate for exports than you pay for imports. Exports might be credited at the utility's avoided cost or a wholesale-based rate, often a fraction of the retail price, while you still pay full retail for electricity you buy. California moved most new customers to a net billing system in 2023, cutting typical export credits by roughly three quarters. Many other states and countries have made similar changes as solar has grown.
Feed-in tariffs, common in Europe in the 2000s, paid a fixed, often generous price for every kWh produced, guaranteed for many years. Most have been reduced or phased out as costs fell.
Under net billing, self-consumption, using your solar power on the spot instead of exporting it, becomes much more valuable. Strategies include running dishwashers, laundry and water heating at midday, charging an EV while the sun shines, and adding a battery. A smaller system sized to match daytime use may also make more financial sense than one sized to cover all annual use.
Step 11 of 13Practice · Chart
A sunny day: solar output vs. home use
Solar peaks at midday, but many homes use the most power in the evening. Under net billing, that mismatch is what makes self-consumption and batteries valuable.
Tap the time when this home draws the most power from the grid.
Tap the point that answers the question, then press Check.
| Item | Solar output | Home use |
|---|---|---|
| 6 am | 0.1 kW | 0.8 kW |
| 8 am | 1.5 kW | 1.2 kW |
| 10 am | 3.6 kW | 0.6 kW |
| Noon | 4.8 kW | 0.5 kW |
| 2 pm | 4.5 kW | 0.6 kW |
| 4 pm | 3 kW | 0.9 kW |
| 6 pm | 1 kW | 2 kW |
| 8 pm | 0 kW | 2.4 kW |
| 10 pm | 0 kW | 1.5 kW |
Step 12 of 13Practice · Match the pairs
Match each arrangement to how exported solar is credited.
Tap an answer, then tap the place where it belongs (or drag it there).
- Net metering
- Net billing
- Feed-in tariff
- Self-consumption
Step 13 of 13Practice · What would you do?
What would you do?
Maria lives where exported solar is credited at 6 cents per kWh but she pays 30 cents per kWh for grid power, with the highest rates in the evening. Her system exports a lot at midday. What will most improve her savings?
Lesson complete!