Roof Space, Panel Layout and Battery Sizing
Check whether a system fits your roof, understand setbacks and roof condition, and size a battery for backup or self-consumption.
Welcome back!
Step 1 of 13Learn
Will it fit?
A residential panel of around 420 W is roughly 1.7 m long and 1.1 m wide, about 1.9 m² (20 square feet). Ten panels need about 19 m², but real layouts need more space than the panels alone:
- Fire code setbacks: many US jurisdictions require clear pathways along roof ridges and edges so firefighters can access and ventilate the roof. These can take a significant part of a small roof.
- Obstructions: vents, chimneys, skylights and dormers break up the usable area.
- Shading: parts of the roof shaded by trees or neighboring buildings may not be worth covering.
- Orientation: in the Northern Hemisphere, north-facing roof sections are often left empty.
A rough rule: each kW of modern panels needs about 5–6 m² (55–65 square feet) of usable roof. A 7 kW system therefore needs about 35–42 m².
If space is limited, options include higher-efficiency panels (more watts per square meter), using east and west faces, a ground-mounted array in the yard, a solar carport or pergola, or community solar, covered later in this course.
Roof condition matters. Panels last 25–30 years or more. If your roof covering will need replacing within about 10 years, replace it first; removing and reinstalling panels later can cost thousands of dollars. Asphalt shingle and metal roofs are the easiest to work with. Tile and slate roofs are possible but cost more. Installers must also confirm the roof structure can carry the extra load, typically around 2–4 pounds per square foot for a racked array.
Step 2 of 13Practice · Work it out
A homeowner wants a 6 kW system. Each 400 W panel takes about 1.9 m² of roof. How many square meters of panel area are needed, ignoring setbacks and gaps?
Step 3 of 13Diagram
What eats into usable roof space
Tap a shape with to see more.
- Usable roof area
- Fire code setbacks
Clear pathways near ridges and edges so firefighters can move and ventilate the roof.
- Vents and chimneys
Pipes, vents and chimneys need clearance around them.
- Skylights
Panels cannot cover them.
- Shaded zones
Areas shaded by trees or nearby buildings may not be worth covering.
- Gaps between panels
Racking and panel shapes leave small gaps that add up.
Step 4 of 13Learn
Batteries: backup or savings?
Earlier you learned what a battery's kWh and kW ratings mean. Sizing one starts by asking what you want it to do.
Goal 1: Backup during outages. List the loads you need during an outage and estimate their daily energy:
- Refrigerator: about 1–2 kWh per day.
- Lights, internet router and phone charging: about 1 kWh.
- Furnace fan or well pump: 1–3 kWh.
- Medical equipment: check its rating.
A typical essential-loads list might total 5–10 kWh per day. One 13.5 kWh battery could cover that for a day or more, and solar can recharge it on sunny days. Running central air conditioning or electric heating, cooking and laundry can push needs to 30–60 kWh per day, which would take several batteries. Check the power rating too: a well pump or air conditioner can draw a startup surge of several kW.
Goal 2: Saving money (self-consumption and time-of-use shifting). Size the battery to store the surplus solar you would otherwise export cheaply, typically enough to cover your evening and overnight use. If your home exports 8 kWh on a typical day and uses about 8 kWh between 5 p.m. and bedtime, a battery of around 10 kWh usable would capture most of that value. A much larger battery would sit partly empty most days.
Goal 3: Off-grid living. Off-grid systems need storage for multiple cloudy days, a larger array for winter, and usually a generator. They are far more expensive per kWh and require careful professional design.
Step 5 of 13Try the calculator
Backup battery runtime
Estimate how long a battery can carry your essential loads overnight without solar recharge.
- Daily essential use
- 5 kWh
- Days of backup without solar
- 2.7 days
- Hours of backup without solar
- 65 hours
Step 6 of 13Practice · Estimate
Use the calculator: with a 13.5 kWh battery and essential loads of 1.5 + 1 + 2.5 kWh per day, about how many hours of backup do you get without any solar recharge?
Step 7 of 13Practice · Sort into groups
Classify each load for a typical outage backup plan.
Tap an item, then tap its group (or drag it there).
Step 8 of 13Note
Step 9 of 13Practice · Choose one
A homeowner's solar system exports about 6 kWh on a typical day, and the home uses about 7 kWh in the evening. Exports earn little, and evening power is expensive. Which battery size best matches the money-saving goal?
Step 10 of 13Compare
Three reasons to buy a battery
| Aspect | Backup | Saving money | Off-grid |
|---|---|---|---|
| Size it by | Essential loads × outage days | Daily surplus and evening use | Several cloudy days of all loads |
| Typical size | One battery, about 10–15 kWh | Roughly your evening use | Many batteries plus a generator |
| Best where | Outages are common | Exports earn little or evening rates are high | No grid connection is available |
| Cost | Moderate | Moderate | High per kWh |
Step 11 of 13Note
Step 12 of 13Practice · Chart
The Garcias' essential loads per day
Tap the biggest daily load.
Tap the slice that answers the question, then press Check.
| Item | Energy |
|---|---|
| Fridge and freezer | 2.5 kWh |
| Furnace blower | 1.5 kWh |
| Lights, internet, phones | 1 kWh |
| Sump pump (storms) | 2 kWh |
Step 13 of 13Practice · Match the pairs
Match each battery specification to what it tells you.
Tap an answer, then tap the place where it belongs (or drag it there).
- Usable capacity (kWh)
- Continuous power (kW)
- Surge or peak power (kW)
- Warranty end-of-life capacity (%)
Lesson complete!