Find a course

Module 2: How the Grid WorksLesson 3 of 1016 min

From Power Plant to Outlet

Trace electricity through transmission, substations and distribution, and calculate why high voltage cuts line losses so dramatically.

Step 1 of 13Learn

The largest machine ever built

The North American power grid has been called the largest machine in the world: thousands of power plants, hundreds of thousands of kilometers of high-voltage lines, millions of kilometers of local wires, and every outlet in every building, all connected and moving in step. Electricity generated in a wind farm in Iowa can light a kitchen in Chicago a fraction of a second later.

The grid has three main parts:

  1. Generation: power plants produce electricity, typically at 10,000 to 25,000 volts (10–25 kV).
  2. Transmission: a step-up transformer raises the voltage to between about 115 kV and 765 kV, and tall steel towers carry it long distances. Transmission is the highway system of the grid.
  3. Distribution: at a substation, step-down transformers reduce the voltage to around 4–35 kV for local lines along streets. A final transformer on a pole or a green box on the ground drops it to the 120/240 V used in US homes (230 V in most of Europe).

The continental US and Canada are divided into three large synchronized networks called interconnections: Eastern, Western and Texas (operated by ERCOT). Within each, all generators spin in lockstep. The three are linked only by a few direct-current ties with limited capacity, which is why a crisis in Texas cannot easily be relieved by power from neighboring states.

From power plant to home: step-up transformer, high-voltage transmission, substation, distribution, homePlant10-25 kVStep-upTransmission115-765 kVSubstationDistribution4-35 kVHome120/240 V

Step 2 of 13Practice · Put in order

Put the path of electricity from a power plant to a home in order.

Drag the items, or use the arrow buttons, to put them in order.

  1. High-voltage transmission lines carry power long distances
  2. Step-up transformer raises voltage to hundreds of kV
  3. Pole or pad transformer reduces voltage to 120/240 V
  4. Substation steps voltage down for local distribution
  5. Generator produces electricity at about 20 kV

Step 3 of 13Diagram

Voltage at each stage from plant to home

The same power changes voltage several times. Tap a layer to see why that level is used.

Voltage at each stage from plant to homeLayer diagram: Transmission line, Subtransmission, Generator terminals, Distribution feeder, Household supply.Transmission line345 kVSubtransmission69 kVGenerator terminals20 kVDistribution feeder12 kVHousehold supply0.24 kV

Tap a shape with to see more.

Typical North American levels; exact voltages differ by utility and country.
Transmission line

Hundreds of kilovolts keep current, and therefore I²R losses, low over long distances.

Subtransmission

Regional lines feeding substations near towns and big factories.

Generator terminals

Generators cannot be insulated for very high voltages, so they produce around 10–25 kV.

Distribution feeder

The lines along streets, typically 4–35 kV.

Household supply

In North America, 240 V split into two 120 V legs at the pole or pad transformer.

Step 4 of 13Learn

Why transmission uses such high voltage

Wires have resistance, so some energy is lost as heat whenever current flows. The power lost in a line is:

P_loss = I2 × R

where I is the current in amperes and R is the line's resistance in ohms. The loss grows with the square of the current. Double the current and losses quadruple.

The power a line delivers is P = V × I (voltage times current). For a given amount of power, raising the voltage lets you lower the current by the same factor. Raise the voltage 10 times and the current falls to one tenth, so losses fall to one hundredth.

Worked example: a plant sends 100 MW down a line with 5 ohms of resistance.

  • At 100 kV: I = 100,000,000 ÷ 100,000 = 1,000 A. Loss = 1,0002 × 5 = 5,000,000 W = 5 MW, or 5% of the power.
  • At 500 kV: I = 200 A. Loss = 2002 × 5 = 200,000 W = 0.2 MW, just 0.2%.

That is the whole reason for transmission towers and transformers. Transformers can only change AC voltages easily, which helped AC win the "war of the currents" in the 1880s and 1890s: Thomas Edison backed direct current, while George Westinghouse and Nikola Tesla promoted alternating current, which could be stepped up for efficient long-distance transmission.

Overall, US transmission and distribution losses average about 5% of the electricity generated. Most of the loss happens on lower-voltage distribution lines, where currents are higher.

Step 5 of 13Try the calculator

Transmission loss calculator

Change the voltage and see how current and losses change for the same delivered power.

Current
435 A
Power lost as heat
0.945 MW
Loss as share of power sent
0.95 %

Step 6 of 13Practice · Work it out

If a utility raises a line's voltage from 115 kV to 345 kV while delivering the same power over the same wire, by what factor do the resistive losses fall? (Enter the factor, for example 4 for "four times smaller".)

Step 7 of 13Learn

Transformers, substations and HVDC

A transformer is two coils of wire wound around a shared iron core. Alternating current in the first coil creates a changing magnetic field, which induces a voltage in the second coil. The ratio of the number of turns sets the voltage change: a coil with 10 times more turns on the output side raises the voltage 10 times (and lowers the current 10 times, since power stays roughly constant). Large power transformers are more than 99% efficient, but they are also huge, custom-built and can take a year or more to replace, which makes them a critical weak point in the grid.

A substation contains transformers plus circuit breakers, switches and protective relays. When a fault happens, such as a tree falling on a line, sensors detect the abnormal current and breakers open within a fraction of a second to isolate the damage before it spreads.

For very long distances or undersea cables, many projects now use high-voltage direct current (HVDC). DC lines have no losses from the constant reversals of AC, need fewer conductors and can connect grids that are not synchronized with each other. The trade-off is expensive converter stations at each end. HVDC usually pays off over several hundred kilometers on land or a few tens of kilometers under the sea. China operates ultra-high-voltage DC lines at up to 1,100 kV carrying hydro, wind and solar power more than 3,000 km to eastern cities.

Step 8 of 13Practice · Select all that apply

Which statements about transmission and distribution are correct? Select all that apply.

Select all that apply.

Step 9 of 13Note

Step 10 of 13Practice · True or false

Most electricity lost between power plants and customers is lost on long-distance high-voltage transmission lines rather than on local distribution lines.

Step 11 of 13Practice · Choose one

A transformer's output coil has 20 times fewer turns than its input coil. If 4,000 V enters, what voltage comes out (ignoring losses)?

Step 12 of 13Tap to reveal

Who does what on the grid

  1. Generators

    Companies or utilities that own power plants, from giant nuclear stations to rooftop solar owners selling surplus.

  2. Transmission owners

    Own and maintain the high-voltage lines and substations. In restructured regions they are paid regulated rates for providing this service.

  3. Balancing authority or grid operator

    Watches frequency and flows minute by minute, dispatches plants and keeps supply and demand matched across its area. In many regions this is an independent system operator.

  4. Distribution utility

    Owns the poles, wires and transformers in your neighborhood, reads your meter and restores power after storms.

  5. Regulators

    In the US, the Federal Energy Regulatory Commission oversees interstate transmission and wholesale markets, state commissions set retail rates, and the North American Electric Reliability Corporation enforces reliability standards.

Step 13 of 13Practice · Fill in the blanks

Fill in the blanks

The power lost as heat in a line equals the current times the resistance. Doubling the voltage for the same delivered power cuts the current in and the losses to one .