How Electricity Is Generated
See how turbines and generators turn motion into electricity, why heat engines waste so much energy, and how solar cells skip the turbine entirely.
Welcome back!
Step 1 of 13Learn
A magnet, a coil and a spinning shaft
In 1831, Michael Faraday moved a magnet through a coil of wire and watched a needle twitch on a meter. He had discovered electromagnetic induction: a changing magnetic field near a conductor pushes electrons along it, creating a voltage. Nearly every power station on Earth still works on that principle.
A generator spins coils of wire inside a magnetic field (or spins magnets inside coils). The faster and stronger the change in magnetic field, the higher the voltage. Because the coils keep reversing direction relative to the magnetic poles, the current flows back and forth, producing alternating current (AC).
What spins the generator? A turbine: a shaft with blades that a moving fluid pushes around.
- Steam turbines: coal, nuclear, biomass, geothermal and concentrated solar plants all boil water into high-pressure steam that blasts through turbine blades.
- Gas turbines: burning natural gas produces hot, expanding gas that spins the turbine directly, like a jet engine bolted to the ground.
- Water turbines: hydropower uses the weight and flow of falling water.
- Wind turbines: moving air turns the rotor, often through a gearbox to raise the speed.
Solar photovoltaic (PV) cells are the big exception. They have no moving parts: sunlight knocks electrons loose in a semiconductor, usually silicon, and the cell's built-in electric field pushes them into a circuit as direct current (DC). An inverter then converts DC into AC for the grid.
Step 2 of 13Diagram
Inside a thermal power plant
Coal, gas, nuclear and geothermal plants all follow the same chain. Only the heat source changes.
Tap a shape with to see more.
- Heat source
Burning coal or gas, fission of uranium, or hot rock deep underground.
- Boiler makes steam
Water is heated into high-pressure steam.
- Steam spins turbine
Steam expands through rows of blades and turns a shaft at high speed.
- Generator
The shaft spins magnets inside coils of wire: Faraday's induction at industrial scale.
- Condenser and cooling
Leftover steam is cooled back into water. This is where most of the fuel's energy leaves as waste heat.
- Step-up transformer
Raises the voltage so the power can travel on transmission lines.
Step 3 of 13Practice · Sort into groups
Sort each technology by how it produces electricity.
Tap an item, then tap its group (or drag it there).
Step 4 of 13Learn
Heat engines and the efficiency ceiling
Any plant that turns heat into motion is a heat engine, and heat engines face a hard limit set by the second law of thermodynamics. The best possible efficiency, the Carnot efficiency, depends only on the temperatures of the hot source and the cold sink:
Maximum efficiency = 1 − T_cold ÷ T_hot, with temperatures in kelvin (°C + 273).
For a steam plant with steam at 550 °C (823 K) and cooling water at 30 °C (303 K): 1 − 303/823 = 0.63, or 63%. Real plants reach only about 33–45% because of friction, imperfect heat transfer and other losses. A nuclear plant runs cooler steam for safety reasons, so it is typically about 33% efficient.
This is why power plants need huge cooling towers or sit beside rivers, lakes and seas: the leftover heat must go somewhere. Thermal power plants are among the largest withdrawers of water in many countries.
Engineers push efficiency up by raising the hot temperature. A combined-cycle gas turbine (CCGT) plant burns gas in a turbine at over 1,300 °C, then uses the hot exhaust to make steam for a second turbine. It reaches 55–62% efficiency, the best of any fossil plant.
Combined heat and power (CHP), or cogeneration, takes another approach: it uses the "waste" heat to warm buildings or run industrial processes, reaching overall efficiencies of 70–90%. Many district heating systems in Scandinavia work this way.
Step 5 of 13Try the calculator
Carnot efficiency limit
Enter the hot and cold temperatures in degrees Celsius. The calculator converts them to kelvin.
- Maximum (Carnot) efficiency
- 63.2 %
- Minimum share of heat rejected
- 36.8 %
Step 6 of 13Practice · Work it out
A geothermal plant uses steam at 227 °C and rejects heat to air at 27 °C. What is its Carnot (maximum possible) efficiency, in percent?
Step 7 of 13Learn
Heat rate: how the industry measures efficiency
Power engineers often express efficiency as a heat rate: the fuel energy, in BTU, needed to generate one kilowatt-hour.
Because 1 kWh = 3,412 BTU, a perfect plant would have a heat rate of 3,412 BTU/kWh. Real plants need more:
Efficiency = 3,412 ÷ heat rate
- A coal plant with a heat rate of 10,000 BTU/kWh is 3,412/10,000 = 34% efficient.
- A combined-cycle gas plant at 6,500 BTU/kWh is about 52% efficient.
- A simple-cycle "peaker" gas turbine at 11,000 BTU/kWh is about 31% efficient.
Lower heat rate means higher efficiency and less fuel per kWh. Heat rate matters for cost: fuel is the biggest operating expense for a fossil plant, so a plant with a lower heat rate can sell power more cheaply and runs more often.
It also matters for emissions. A plant's CO2 per kWh equals fuel burned per kWh times the carbon content of that fuel. Coal contains more carbon per BTU than natural gas, and coal plants usually have higher heat rates, so coal emits roughly twice as much CO2 per kWh as an efficient gas plant: about 1 kg versus about 0.4 kg.
For wind, solar and hydro, heat rate is meaningless because there is no fuel. Statistics agencies use different conventions to fit them into primary energy totals, which is one reason energy statistics can disagree.
Step 8 of 13Practice · Work it out
A gas power plant has a heat rate of 7,000 BTU/kWh. What is its efficiency to the nearest whole percent?
Step 9 of 13Practice · Chart
Typical conversion efficiency by technology
Which heat engine converts the largest share of its fuel energy into electricity?
Tap the bar that answers the question, then press Check.
Step 10 of 13Tap to reveal
Five ways to spin a generator
Coal steam plant
Pulverized coal burns in a boiler, steam drives a turbine. Typically 33–40% efficient. Slow to start and ramp, so traditionally run as baseload.
Nuclear steam plant
Fission heat in the reactor makes steam. About 33% efficient, very high capacity factor, runs best at steady full output, and refuels every 18–24 months.
Combined-cycle gas
A gas turbine plus a steam turbine running on its exhaust heat. Up to about 60% efficient, ramps within tens of minutes to hours.
Simple-cycle gas peaker
A gas turbine alone. Starts in minutes but is only about 30–40% efficient, so it runs only during peaks when prices are high.
Hydro
Water spins turbines at around 90% efficiency in converting the water's energy. Can start in minutes and follow demand closely, but depends on rainfall and reservoir levels.
Step 11 of 13Practice · Choose one
Why are combined-cycle gas plants more efficient than simple-cycle gas turbines?
Step 12 of 13Note
Step 13 of 13Practice · True or false
A nuclear power plant converts radiation directly into electricity without using a turbine.
Lesson complete!